A practical framework for evaluating sensor performance, data reliability and long-term quality assurance in urban monitoring networks. A Guide for Municipalities and Public Procurement.
Modern urban air quality monitoring networks provide spatial and temporal resolution that conventional reference stations alone cannot achieve. For municipalities investing in this infrastructure, the essential question is how measurement performance can be quantified, verified and maintained over time. The revised EU Ambient Air Quality Directive (EU) 2024/2881 establishes data quality objectives for indicative measurements, providing a technical foundation for specifying and evaluating urban monitoring networks. Using real-world PM10 measurements from Cluj-Napoca, Romania, this article demonstrates how uRADMonitor evaluates instrument performance against national reference stations and extends this methodology into an automated, self-calibrating monitoring network.
The integration of Romania’s national reference network, the RNMCA stations, into the uRADMonitor platform enables comparisons with reference measurements wherever suitable stations are available. The sensor intercomparison and calibration tool computes the performance metrics presented below directly from operational data.
Real-world field performance: Cluj-Napoca
We take one uRADMonitor CITY unit, 1C000056, installed at the Gheorghe Șincai high school, and the nearby RNMCA reference station A00069A4 (CJ-2). The parameter is PM10, the window is seven days (19 to 26 November 2026), averaged hour by hour. The two instruments are a few kilometres apart: not co-located, which matters for how we read the results later.

Two things are visible immediately. The sensor tracks the reference well: every episode, including the sharp peak on 25 November, appears in both traces at the same time. And the sensor reads low: the blue line sits under the orange one almost everywhere. These are two different characteristics, and the metrics below separate them cleanly.
Quantifying measurement performance
Coefficient of determination (R²): does it follow the pattern?
The coefficient of determination R² describes the proportion of variance explained by a regression model. For a simple linear regression with an intercept, it is the squared Pearson correlation coefficient. A high R² indicates strong linear association, but does not establish agreement in absolute concentration. Here R² is 0.62, a useful result for instruments operating several kilometres apart, where local pollution sources and spatial variability also influence the comparison.
Correlation alone does not establish measurement accuracy. An instrument can have R² of 0.99 and still systematically overestimate concentrations by 60%. This is why bias, RMSE and uncertainty are essential complementary metrics.
Slope and bias: how far off, and in which direction?
Linear regression describes the relationship between sensor and reference concentrations. A slope of 1 and an intercept of 0 describe ideal agreement. Bias is the mean signed difference between sensor and reference readings. The reported regression slope is 0.75, while the bias is −2.5 µg/m³, indicating that the instrument reads low on average. The scatter plot illustrates this systematic difference.

Because this error is systematic (a consistent scale and offset), it is largely fixable. That is what calibration does.
RMSE: the typical error, before and after correction
RMSE (root mean square error) quantifies the magnitude of the differences between sensor and reference in µg/m³, giving greater weight to larger deviations. It combines systematic bias and residual dispersion: RMSE² = bias² + scatter², where scatter is the standard deviation of the paired errors calculated with the population convention.
A linear correction improves agreement with the reference, reducing RMSE from 3.9 to 2.8 µg/m³, an improvement of approximately 28%. The remaining difference includes residual instrument disagreement and spatial variability between the monitoring locations.

Measurement uncertainty (U): the metric that actually decides
Relative expanded measurement uncertainty is a central metric in the European data quality framework. It expresses uncertainty relative to a specified concentration, generally using a coverage factor of approximately two. The intercomparison tool estimates uncertainty using an approach based on the EU Guide for the Demonstration of Equivalence, evaluated here at 45 µg/m³ for PM10.
U is not R² and bias added together. It combines the random scatter that survives calibration (close to the corrected RMSE) with the residual scale and offset error at the limit value, then doubles it and divides by that limit value. R² does not enter it at all. For this sensor U comes out at 13%, against an indicative data quality objective of 50% for PM10. The estimated uncertainty is just 26% of the 50% benchmark used in this assessment, a strong result under real urban operating conditions.

Why U and not R²? Because U catches the failure R² is blind to. Take a sensor that reads exactly twice the truth every hour: its R² is a perfect 1.0, but its U is enormous, and it would fail. U rewards agreement, not just correlation. That is precisely why the directive is written in terms of uncertainty.
Data capture: is there enough data to trust the number?
Data availability is essential for reliable environmental reporting. The uRADMonitor CITY instrument reported 100% hourly data capture during the evaluated period, with 167 paired hourly observations available for the comparison. Minute-level reporting and integrated connectivity support detailed analysis of pollution episodes and long-term trends.
Field performance assessment results
| Metric | Value | What it tells you |
|---|---|---|
| R² | 0.62 | Linear association with reference |
| Slope | 0.75 | Reported regression slope |
| Bias | −2.5 µg/m³ | Reads low on average |
| RMSE (raw → corrected) | 3.9 → 2.8 µg/m³ | Approximately 28% improvement after correction |
| U (uncertainty) | 13% (benchmark 50%) | Well below the indicative uncertainty benchmark |
| Data capture | 100% | Enough valid data for the period |
Automated parameter-level quality assessment
The network does not treat every sensor the same way. Each sensor, for each parameter, falls into one of three classes, decided automatically from exactly these metrics:
| Class | Meaning | How it is served |
|---|---|---|
| Corrected | Tracks a reference well and passes the uncertainty check after calibration | Transfer function applied, served reference-anchored |
| Uncorrected | Works, but no usable reference nearby or the fit does not qualify | Served raw, with a quality flag |
| Faulty | A parameter is stuck, out of range, or decorrelated from its neighbours | That parameter is dropped, others kept |
The classes are per parameter, not per device: a unit can be corrected on PM10, uncorrected on PM2.5, and have another parameter flagged faulty, all at once. And “faulty” is not just a range check. A sensor can read perfectly plausible numbers and still be broken if it no longer tracks its neighbours. Detecting that needs the correlation of a sensor against the local reference composite, not just a min/max test, which is one of the things the integrated RNMCA data made possible
From individual instruments to self-calibrating monitoring networks
The example above is one sensor against one reference. The network does this at scale and without manual work. Rather than pin each sensor to its single nearest station, the system builds an airshed composite: the hourly median of all healthy reference stations in a metropolitan area. A composite is a steadier, more representative target than any one station, and it is quality-checked before use, a reference that has drifted or is spatially incoherent is detected and excluded from the composite rather than poisoning it.
A daily automated process then, for every airshed and every parameter: builds the composite, screens the reference stations for coherence, fits each nearby sensor out-of-sample, decides its class, and writes a timestamped correction that the data API applies when corrected values are requested. The whole thing is config-driven: as more national networks are integrated after RNMCA, airsheds and corrections extend automatically, with no change to the code.
An essential part of the calibration methodology is out-of-sample validation. Correction functions are evaluated on data separate from the fitting period before being accepted for operational use. Where a correction does not qualify, raw measurements remain available with their quality status.
For municipalities, this architecture introduces an important operational advantage. Measurement performance is no longer assessed exclusively during procurement or scheduled maintenance. The monitoring infrastructure itself generates information about instrument performance, helping operators identify changes in behaviour, investigate abnormal measurements and apply validated corrections throughout the lifetime of the network.
Independent validation and continuous field assessment
The Cluj-Napoca comparison demonstrates operational performance across two different urban locations. Its uncertainty estimate includes spatial variability as well as instrument disagreement. Dedicated co-location campaigns and continuous field comparisons provide complementary evidence of measurement performance.
uRADMonitor instruments have an established history of independent performance evaluation. The MODEL A3 has been evaluated through South Coast AQMD’s AQ-SPEC programme, Romania’s INCD-ECOIND and the AIRLAB Microsensors Challenge. The broader evaluation experience includes MODEL A4, MODEL CITY, MODEL INDUSTRIAL and SMOGGIE, with award-winning results for uRADMonitor instruments at AIRLAB. The technology is also used in peer-reviewed scientific research.
The CEN/TS 17660 series provides technical methods for evaluating air quality sensor systems. Independent evaluations establish documented instrument performance, while automated reference-based assessment extends quality assurance into daily operation. Together they support equipment selection, maintenance planning and long-term municipal network management.
Recommended technical requirements for municipal air quality monitoring networks
Municipal procurement should address both initial instrument performance and the quality of the data produced throughout operation. The following performance-based criteria provide a practical starting point for technical specifications, adapted to the pollutants, monitoring objectives and applicable regulations. Equivalent technical solutions can be assessed using the same verification methods.
| Requirement | Recommended technical specification | Verification method | uRADMonitor |
|---|---|---|---|
| Measurement performance | Documented performance against applicable EU data quality objectives | Relevant independent reports | ✓ |
| Independent evaluation | Third-party evaluations relevant to the offered instruments and pollutants | Published test reports | ✓ |
| Temporal resolution | Minute-level reporting where appropriate | Functional demonstration | ✓ |
| Reference integration | Integration with official reference monitoring data | Platform demonstration | ✓ |
| Continuous quality assurance | Automated statistical performance assessment | Performance reports | ✓ |
| Automated calibration | Reference-based correction with out-of-sample validation | Validation records | ✓ |
| Calibration traceability | Timestamped correction coefficients | Calibration records | ✓ |
| Fault detection | Automated parameter-level diagnostics | Diagnostic demonstration | ✓ |
| Data availability | Defined valid data capture and operational availability targets | Availability reports | ✓ |
| Interoperability | Documented API and machine-readable exports | API documentation and sample exports | ✓ |
| Historical data access | Access to complete retained measurement archives | Archive export demonstration | ✓ |
| Institutional access | Separate administrative and read-only permissions | Functional demonstration | ✓ |
| Operational resilience | Local data access without internet connectivity where required | Local access demonstration | ✓ |
uRADMonitor supports these operational requirements through its data API, Archive Download, institutional access permissions and Direct Local Access on supported instruments. These capabilities allow municipalities to reuse environmental data in GIS, reporting and research applications.
A proven approach to municipal air quality monitoring
The combination of independently evaluated instruments, distributed monitoring infrastructure and automated reference-based quality assessment represents a significant advancement in urban air quality monitoring. The Cluj-Napoca example demonstrates an estimated uncertainty of 13%, reported hourly data capture of 100% and a 28% reduction in RMSE through linear correction. Municipalities can extend spatial coverage at substantially lower infrastructure cost than deploying conventional reference stations at every monitoring location, while benefiting from continuous statistical performance assessment.
Live air quality and radiation map by uRADMonitor
That is why cities are already building their air quality monitoring on uRADMonitor networks: Cluj-Napoca, as part of the EU URBREATH project, Bistrița, Bucharest, Timișoara, Brașov, and many others. These deployments demonstrate the practical application of distributed monitoring infrastructure in municipal projects.
You can run the same analysis on any uRADMonitor or RNMCA sensor in the intercomparison and calibration tool. For independent, third-party evaluations of uRADMonitor hardware, see the model A3 field reports from AQ-SPEC (SCAQMD), the AIRLAB Microsensors Challenge 2023, and INCD-ECOIND.
Municipal Air Quality Monitoring : Public Procurement Resources
Air quality monitoring solutions for municipalities and local authorities
Drawing on extensive deployment experience in Bucharest, Cluj-Napoca, Timișoara, Brașov, Bistrița and other Romanian cities, uRADMonitor provides technical consultancy to municipalities and local authorities for the design, implementation and optimisation of air quality monitoring networks. In Romania, uRADMonitor instruments are also available through the Electronic Public Procurement System (SEAP/SICAP).
Our expertise covers instrument selection, network sizing, monitoring site optimisation, integration with existing municipal infrastructure and achieving an optimal balance between investment, spatial coverage and measurement performance.
To support municipalities and environmental consultants in preparing public procurement projects, MAGNASCI provides a free, editable technical specification template for municipal air quality monitoring networks, based on EU Directive 2024/2881, relevant European technical standards and practical deployment experience.
The document includes recommended technical requirements, measurement performance criteria, continuous quality assurance, data interoperability, acceptance testing and a compliance matrix for evaluating technical proposals. It can be adapted to the specific objectives of each project and the applicable national procurement legislation.
Download the free technical specification template or request a technical proposal tailored to your municipality’s needs.
Liked this? Get monthly air quality findings.
One email a month from the uRADMonitor network. Unsubscribe anytime.


codemore code
~~~~