A municipal monitoring network should be designed around decisions, not simply the number of instruments purchased. The objective is to identify spatial differences, investigate pollution episodes and assess the effects of local interventions. Directive (EU) 2024/2881 provides the regulatory context for ambient air assessment; municipal networks can complement official monitoring.
Start with monitoring objectives
Identify traffic corridors, residential exposure, industrial influence and urban background conditions. Define the decisions each dataset will support and the averaging periods needed. PM2.5 and PM10 provide a useful starting point; NO₂, O₃ and other gases should be selected according to local sources and the required measurement performance.
Select sites before selecting quantities
Map roads, population, schools, industrial sources, prevailing winds, terrain and existing reference stations. Stratify locations into traffic, urban background, residential and source-oriented sites. Reserve sites for comparison with reference instruments.
Use Annex IV of the directive as the basis for siting where measurements are intended for official assessment. Document inlet height, distances to obstacles, airflow, nearby sources, power, communications and photographs. Avoid treating every sensor as representative of an identical circular area. Annex IV of Directive (EU) 2024/2881 – Assessment of ambient air quality and location of sampling points.
Determine network density
There is no universal EU requirement for one indicative sensor per square kilometre. As a planning example, a 50 km² city with 20, 40 or 80 nodes has nominal densities of 0.4, 0.8 or 1.6 nodes/km². These figures are budgeting scenarios, not regulatory minima or guarantees of street-level resolution. Adjust the distribution to source variability and population exposure.
A mixed fleet can use MODEL A3 for distributed multiparameter observations and MODEL CITY at selected locations requiring dedicated gas measurements. Specify the actual configuration and independently documented performance for each pollutant.
Integrate reference observations and quality assurance
Use co-location campaigns to establish comparability, retaining raw data and recording instrument revisions, maintenance and corrections. Validate corrections on data not used to fit them. A nearby reference station is useful for operational comparison, but local concentration differences must not be automatically removed as sensor error.
Track data capture, instrument uptime, drift and parameter-level anomalies separately. Define escalation procedures, inspection intervals and acceptance criteria before installation.
Deploy in phases
Begin with a representative pilot across site types. Review communications, data availability, site accessibility and measurement performance before expanding. Use an inventory with coordinates, instruments, firmware, installation photographs and maintenance history.
At acceptance, demonstrate data export, API access, alarms where specified, data quality flags and the agreed reporting workflow. Reserve operating funds for the full lifecycle, not only acquisition.
A municipal example: Cluj-Napoca
The Cluj-Napoca URBREATH deployment combines MODEL A3 and MODEL CITY instruments, with public access to readings through the municipality. It illustrates the value of combining instrument types and involving local research partners.
Related resources
Technical specifications and tender template
Request a technical proposal tailored to your municipality.
Request a technical proposalLiked this? Get monthly air quality findings.
One email a month from the uRADMonitor network. Unsubscribe anytime.