Electronics Goldmine has these on sale, and I’ve been able to get these hooked up – although, there’s no options in the source for them:
G24780 ^ CI-21BG Russian Beta & Gamma Geiger Tube
How easy/hard would it be to add these to the detector.h and detectors.cpp to get them to work? Right now, it’s seeing it as a SBM-20, and I know I would need to recompile.
The only specs I can find on them are:
Working range of Dose POWER: 50R/h
Working Voltage: 350-450V
Maximum registering range: 1000 Roentgen/hour
Plateau Length/ Inclination: 100V/0.15%/V
Current sensitivity: 0.4 – 0.7 uA/R/h
Maximum current: 12-20 uA
Length: 70mm
Diameter: 10mm
Edit: I found some conversion factors here: https://radmon.org/index.php/forum/geiger-muller-tubes/43-conversion-factors?start=0
Do you need help with the firmware? I can compile it for you, to include this new tube. Let me / us know.